Synopsis: Your arrow board could encounter power issues over time. This could be caused by bad batteries or an issue with one of the components.
- Level: Medium
- Time required: 5 minutes
- Additional equipment required: Voltmeter, replacement parts (optional)
1. Try powering on the arrow board
Figure 1 - 15-lamp arrow board controller
Figure 2 - 25-lamp arrow board controller
2. Check for power & LEDs to the controller (J4 connector)
Note: To gain access to the connectors, you must remove the controller by unscrewing the 4 screws in each corner.
Figure 3 - Controller power connector
3. Check for power to the lamps (J6 connector)
Figure 4 - Lamp power connector
If you see any dim or shut-off lamps, check the positive and negative connectors on the back of them, or simply swap them out with a different lamp.
4. Check the batteries
Figure 5 - Battery compartment
Figure 6 - Battery & power wiring
4.1. If your unit has a charger option, try recharging your batteries if you have some that are too low
Figure 7 - Charger wiring
If you require any additional help, contact our toll-free number at 1-888-488-7446 or email us at support@ver-mac.com