G3 Arrow Board Power & Lamp Error Troubleshooting

Synopsis: Your arrow board could encounter power issues over time. This could be caused by bad batteries or an issue with one of the components.

  • Level: Medium
  • Time required: 5 minutes
  • Additional equipment required: Voltmeter, replacement parts (optional)

                                                                                                                                                              

1. Try powering on the arrow board

mceclip0.png

Figure 1 - 15-lamp arrow board controller

mceclip1.png

Figure 2 - 25-lamp arrow board controller

 

2. Check for power & LEDs to the controller (J4 connector)
Note: To gain access to the connectors, you must remove the controller by unscrewing the 4 screws in each corner.

mceclip0.png

Figure 3 - Controller power connector

 

3. Check for power to the lamps (J6 connector)

mceclip1.png

Figure 4 - Lamp power connector

If you see any dim or shut-off lamps, check the positive and negative connectors on the back of them, or simply swap them out with a different lamp. 

 

4. Check the batteries

mceclip1.png

Figure 5 - Battery compartment

mceclip0.png

Figure 6 - Battery & power wiring

4.1. If your unit has a charger option, try recharging your batteries if you have some that are too low

Figure 7 - Charger wiring

 

If you require any additional help, contact our toll-free number at 1-888-488-7446 or email us at support@ver-mac.com